POWER
REQUIREMENTS
Voltage : 120 VAC, 50/60 Hz
Current : 0.66 A max (depends on load)
Power : 80 W max (depends on load)
.
INPUT CONNECTIONS
Two AWG 18 leads, 8 inches long,
or power cord, 8 ft long, black or white.
.
CONTROL (OPTIONAL)
Red (+) and brown (-) wires can be
connected to an electronic controller to
modulate neon brightness or to gate the unit
on and off.
Maximum "on" voltage : 1.20 V
Minimum "off" voltage : 2.50 V
Control current : 1.6 mA (5 V control voltage)
Absolute max. control voltage : 15 V
.
OUTPUT CHARACTERISTICS
Output is isolated from input for maximum
flexibility of application. Shorted output
supplies
the rated
current. Open circuit or excessive load will cause the unit to
shut down, but special circuit will attempt
to automatically restart power up to three
times to avoid nuisance trips.
Voltage : 8KV AC max. (actual voltage
depends
on load and will be
equal
to or lower than this value.)
Current : 20 mA
.
OUTPUT CONNECTIONS
GTO-10 leads, 12 inches long.
|
DIMENSIONS
4.00 x 1.40 x 0.90 (max) inches
.
MOUNTING
Unit is mounted with two 8-32 x 3/4 inch
nylon screws and nuts (provided).
.
FOOTAGE CHART
|
8 mm
|
9 mm
|
10mm
|
12mm
|
15mm
|
Neon
|
10 ft
|
13 ft
|
15 ft
|
18 ft
|
20 ft
|
Argon
|
12 ft
|
15 ft
|
17 ft
|
20 ft
|
20 ft
|
.
Maximum footage is shown, no minimum
limit exists. Footage includes one pair
of electrodes. Deduct one foot only for
each additional pair.
.
This unit complies with requirements in
UL 2161 standard, including secondary
ground fault protection requirements.
It is suitable for indoor or outdoor use.
CAUTION
This device produces high voltage at
high frequency and can create potential
danger if not applied and installed properly.
This device is provided with an automatic
reset function - disconnect power before
servicing.
.
HOW TO ORDER
Model
|
supplied with
|
UL std
|
Gen3-8K20
|
input leads
|
2161
|
Gen3-8K20/7B |
black power cord |
2161
|
Gen3-8K20/7W |
white power cord |
2161
|
Gen3-8K20/C
|
control input
|
2161
|
|